Enhancing patient safety and precision for treatments on Halcyon®, Ethos™ and (coming soon) Radixact® linear accelerators
Visibility Inside the Bore
Shadowing inside the bore during radiotherapy treatments can make accurate patient monitoring challenging, potentially impacting treatment precision¹.
AlignRT InBore combines the benefits of ceiling-mounted AlignRT cameras for patient setup with a dual camera system mounted on a ring within the bore. This helps maintain full visibility of the tracking region through setup, imaging and treatment.
Published data from UCSD demonstrates that using AlignRT for setup can reduce treatment times, reduce repeat imaging and improve patient position accuracy by reducing residual rotational errors².
Built-In Tools
The following tools come standard with the latest version of AlignRT InBore:
A clear, photorealistic image of your patient supports accurate identification and precise ROI placement.
Provides fast, customizable documentation for treatments, QA, and calibrations enhancing clinical confidence and compliance.
See even the smallest anatomical changes in real time. With intuitive color mapping, the Deformation Tool supports smarter decisions—helping you know when to adjust ROIs or to re-scan.
Get instant insight into ROI performance as you work. AlignRT helps you fine-tune ROI size and shape for optimal tracking and faster setups.
Instantly verify SSDs at a single gantry angle—without the need for manual room checks or other separate processes. Just one click, and you’re ready.
Position patients faster and more accurately with one-click couch value transfers. This seamless automation tool eliminates manual entry errors and enables one-step setups.
Logging into AlignRT is now effortless and secure. Smart Sign-On (using Microsoft’s Active Directory) links to your clinic’s existing credentials to eliminate extra logins, while aligning with your cybersecurity policies. With Smart Sign-On, onboarding new users is fast, automatic, and secure.
Published clinical data shows:
5% faster total treatment time²
Accurate and reproducible DIBH³
High accuracy for setup and monitoring⁴
Hear from users on their clinical experiences:
“AlignRT InBore guided breath-hold provides reliable intra-fraction motion control with appropriate margins for whole breast and abdominal lymphoma patients.”
Xinran Zhong, PhD, DABR, University of Texas Southwestern
“Setup is a lot faster than what it used to be.”
Gail Anastasi, Principal Radiotherapy Physicist, Royal Surrey Cancer Centre
What our customers say
Frequently Asked Questions
Yes, through Varian’s Verification and Validation Process, AlignRT InBore is compatible with Halcyon versions 2.0, 3.0, 3.1, and 4.0 and Ethos versions 1.0 and 2.0.
AlignRT InBore for Radixact is currently in development, with commercial availability expected in late 2025, depending on the territory and when the associated regulatory clearance is obtained. Vision RT is working with Accuracy to ensure the compatibility and connectivity of AlignRT InBore for Radixact.
Varian is currently developing an interface to connect motion management technology with Halcyon and Ethos Radiotherapy Systems. This architecture, similar to MMI on TrueBeam, is expected to be released soon. Once the interface specification is available, Vision RT will have access through Varian’s Interoperability program.
- Jadhav A, Gupte A, Dandekar PR, Rasal S, Awate O, Dhoundiyal M. (2025). Ensuring Clinical Readiness: Commissioning, Acceptance and Performance Testing of Closed Bore Linear Accelerator Compatible Surface Guided Radiotherapy System. J Med Phys. 2025 Jan-Mar;50(1):148-154.
- Flores-Martinez, E., et al. (2020). Assessment of the use of different imaging and delivery techniques for cranial treatments on the Halcyon linac. J Appl Clin Med Phys. 2020 Jan;21(1):53-61.
- Lorchel, F., Nguyen, D., et al. (2022). Reproducibility of Deep-Inspiration Breath Hold treatments on HalcyonTM performed using the first clinical version of AlignRT InBoreTM: Results of CYBORE study. Clinical and Translational Radiation Oncology, 35, pp.90–96.
- Oku, Y., et al. (2023). Characteristics of detection accuracy of the patient setup using InBore optical patient positioning system. Radiol Phys Technol. 2023 Dec;16(4):532-542.
Radixact® is a registered trademark of Accuray. Halcyon® & Ethos™ are registered trademarks of Siemens Healthineers. The use of Halcyon® & Ethos™ herein is for identification purposes only. Use of these marks does not indicate sponsorship, affiliation, endorsement, or approval by Siemens.
*AlignRT InBore for Radixact is not cleared for clinical use in the United States.