AlignRT InBore: Increased Efficiency for Bore-Based System

AlignRT InBore: Increased Efficiency for Bore-Based System

Overview

Institution Type: Academic Hospital
Location: Boston, Massachusetts
SGRT System: AlignRT InBore
Years with system: 3 years
Linac: Varian Ethos
Cancer types treated: Prostate

Download a PDF copy of this case study

GOALS

Dana-Farber/Brigham Cancer Center (DFBCC) was an early adopter of AlignRT on their linear accelerators. They were able to improve their workflows and treat patients more efficiently without tattoos and marks. They wanted the same efficiency, accuracy and monitoring for their bore-based system. Specifically, they needed to monitor the patient inside the bore to detect any movement the human eye might not capture.

SAFETY

DFBCC learned through their adoption of AlignRT on their linear accelerators that patients can move after setting them up.
They wanted a solution that monitored their patients from beginning to end of treatments to ensure safety.

EFFICIENCY

With the growth of their Genitourinary program (GU), DFBCC treats 40-60 patients a day on their bore-based system.
They needed an SGRT solution that would help them keep the same treatment times and efficiency with their prostate and bladder patients.

CLINICAL INNOVATION

DFBCC is recognized by U.S. News & World Report as one of the nation’s top five cancer centers. Clinical innovation is at the forefront of their mission. They needed technology that would help give their patients cutting-edge treatments with the best possible outcomes.

SOLUTION

ALIGNRT INBORE

Dana-Farber/Brigham Cancer Center chose the AlignRT lnBore system to specially monitor patients inside the bore to detect any movement the human eye might not capture (i.e., patient arm shift, cough, sneezing).

POSTURAL VIDEO & REAL TIME COACH

The real-time video feed gives DFBCC staff guidance from multiple angles, letting them know when and where the patient is out of position. It also helped minimize their setup time and stay consistent with their patient volume. Real Time Coach was used to assist patients visualize their breath, knowing when to breath in and out, during their advanced procedures (LIBH).

SITE VISIT

DFBCC visited a Vison RT Centers of Excellence to train on how AlignRT was implemented in their clinic and the team approach they took to establish best practices. This, along with participation in an SGRT annual meeting, helped adoption of SGRT technology and tattoo and mark-free treatment.

RESULTS

10-MINUTE TIME SLOTS
InBore helped treatment times stay at 10-minute time slots and in most cases reduce them to 8 minutes.
INCREASED PATIENT VOLUME

Patient volume of 40-60 patients per day was able to be maintained, helping manage the GU one-year program growth of 32%.

REDUCED RE-IMAGING

Using AlignRT lnBore helped reduce re-imaging by 50%, helping reduce treatment times and maintain time slots.

TATTOO & MARK-FREE TREATMENTS

DFBCC adopted totally tattoo and mark-free treatment for all their patients.

FUTURE PLAN

Dana-Farber/Brigham Cancer Center is now offering Adaptive Radiotherapy and introducing Lower Inspiration Breath Hold (LIBH), a technique used for breast treatment in which dose is reduced to the heart and lungs. The main goal of LIBH is to stop the internal organ motion to improve image quality thereby improving contouring. AlignRT InBore has been essential to this technique workflow to capture a breath hold during treatment delivery.